Direct burial in the earth is permitted. May be installed as interior wiring in wet, dry, or corrosive locations as specified by the NEC May be installed as nonmetallic-sheathed cable as specified in NEC Section 340.10(4). May be installed in locations with temperatures up to 90°C but with the ampacity limited to that of 60°C conductors.
Get free shipping on qualified Direct Burial , UF-B Wire or Buy Online Pick Up in Store today in the Electrical Department.
This item: 10/2 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (150ft Cut) $136.06 ($0.91 / 1 Ft) Only 14 left in stock – order soon. Ships from and sold by Cable Cabana.
8/2 Underground Feeder Cable UF-B Copper 600V Allowable Ampacity for 8/2 Underground Feeder Cable UF-B Copper 600V ( Direct Burial ): 40 Allowable Ampacity for 8/2 Underground Feeder Cable UF-B Copper 600V in Duct: 40 Applications: An underground feeder cable’s prime purpose is to bring the power from the residential, commercial, and industrial buildings to.
6/3 Underground Feeder Cable UF-B Copper 600V Allowable Ampacity for 6/3 Underground Feeder Cable UF-B Copper 600V ( Direct Burial ): 55 Allowable Ampacity for 6/3 Underground Feeder Cable UF-B Copper 600V in Duct: 55 Also Known As: 6/3 Copper Underground Feeder Cable, 6/3 Copper Direct Burial Feeder Cable, 6/3 Branch Circuit Wiring Cable, 6/3 UF-B Wire, 6/3 Copper Direct Earth Burial .
Type UF B cable is made for direct burial underground without the use of conduit or other piping, and is also gray in color and is marked as type UF B cable to denote the difference between it and the regular type UF cable, which is not suitable for direct burial outside of.
Southwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial . Multiple conductor UF-B cable may be used for, UF is designed and approved for direct burial . For direct burial , the required depth is 24 or less depending on AHJ or if it’s under pavement, you’ll have to read the Table 300.5 in the NEC to get the exact details. Your deck is not considered a building in the NEC so it will need to be buried.
Type UF B cable is made for direct burial underground without the use of conduit or other piping, and is also gray in color and is marked as type UF B cable to denote the difference between it and the regular type UF cable, which is not suitable for direct burial outside of